title: Understanding 5 ppm Bilge Alarm Requirements
description: Understand 5 ppm bilge alarm requirements for Transport Canada and DNV CLEAN Design, and how to check your SMART BILGE configuration.
---

[Skip to content](https://hub.rivertrace.com/knowledge/understanding-5-ppm-bilge-alarm-requirements#main-content)

English

Show submenu for translations

[Submit a request](https://hub.rivertrace.com/knowledge/kb-tickets/new)

[![Rivertrace-Logo-Blue-on-White](https://hub.rivertrace.com/hs-fs/hubfs/Rivertrace%20Logos/Rivertrace-Logo-Blue-on-White.jpg?width=412&height=150&name=Rivertrace-Logo-Blue-on-White.jpg)](https://www.rivertrace.com)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- [Submit a request](https://hub.rivertrace.com/knowledge/kb-tickets/new)
- [Cant find what you need? Contact our remote support team.](mailto:remotesupport@rivertrace.com)

[Cant find what you need? Contact our remote support team.](mailto:remotesupport@rivertrace.com)

 How can we help you?

- There are no suggestions because the search field is empty.

1. [Knowledge Base](https://hub.rivertrace.com/knowledge)
2. [SmartBilge](https://hub.rivertrace.com/knowledge/smartbilge)

# Understanding 5 ppm Bilge Alarm Requirements

## The standard international limit associated with machinery-space bilge water is 15 ppm, but some vessels may be required to operate to a stricter 5 ppm limit. 

Two requirements commonly encountered are **Transport Canada requirements for Canadian inland waters** and **DNV CLEAN Design class requirements**.

Although both refer to 5 ppm, it is important to understand the equipment configuration required.

### Transport Canada – 5 ppm

For Canadian inland waters, the discharge requirements are reduced from 15 ppm to **5 ppm**.

Transport Canada's **TP 12301 – Standard for 5 ppm Bilge Alarms for Canadian Inland Waters** requires the alarm device to be **pre-set by the manufacturer to activate when the effluent exceeds 5 ppm**.

A standard SMART BILGE allows alarm settings to be configured within its permitted range. Simply changing the alarm point onboard to 5 ppm should therefore **not be confused with a dedicated factory-configured 5 ppm version**.

### DNV CLEAN Design

DNV CLEAN Design requirements can also require the bilge alarm to operate at **5 ppm**.

Where the applicable DNV requirement calls for a dedicated 5 ppm arrangement, Rivertrace can provide:

- a **factory-configured 5 ppm control module**, preventing the applicable alarm limit from being increased onboard; and
- a **flow switch**, where required, to confirm sample flow through the measuring cell while the monitor is operating.

The factory configuration is identified on the equipment and supporting Rivertrace documentation.

### How do I know what I have?

> **Check the alarm settings on your SMART BILGE control module.**
> 
> Go to **Settings → Alarm Point**.
> 
> If the alarm point can be changed above 5 ppm, the unit has **not been restricted as a dedicated 5 ppm configuration**.
> 
> If the alarm setting is restricted to the dedicated 5 ppm configuration, check the equipment label, serial number and certification to confirm the configuration.

**Related article:** [SMART BILGE + 5PPM Type Approval Installation guide -Customer procedure](https://hub.rivertrace.com/knowledge/smart-bilge-5ppm-type-approval-installation-guide-customer-procedure) 

### What happens at recalibration?

The **measuring cell calibration and 5 ppm alarm configuration are separate functions**.

The measuring cell measures the oil concentration. The alarm configuration is held within the **control module**.

Therefore, replacing the measuring cell as part of the normal **five-year calibration cycle does not change the vessel's 5 ppm alarm configuration**.

### Need to confirm your 5 ppm configuration?

If you are unsure whether your SMART BILGE is **user-set to 5 ppm or factory configured for a specific 5 ppm requirement**, send Rivertrace the equipment serial number and a photograph of the control module.

We can confirm the existing configuration and advise whether any changes are required for the applicable standard.

- [Smart ODME](https://hub.rivertrace.com/knowledge/smart-odme)
- [SmartBilge](https://hub.rivertrace.com/knowledge/smartbilge)
- [Smart Bilge+ Plus](https://hub.rivertrace.com/knowledge/smart-bilge-plus)
- [Smart PFM](https://hub.rivertrace.com/knowledge/smart-pfm)
- [OCD CW](https://hub.rivertrace.com/knowledge/ocd-cw)
- [Smart ESM](https://hub.rivertrace.com/knowledge/smart-esm)
- [OCD Xtra](https://hub.rivertrace.com/knowledge/ocd-xtra)
- [Smart 50M](https://hub.rivertrace.com/knowledge/smart-50m)
- [Smart Turbidity](https://hub.rivertrace.com/knowledge/smart-turbidity)
- [Sample conditions and general techniques](https://hub.rivertrace.com/knowledge/sample-conditions-and-general-techniques)
- [General FAQs](https://hub.rivertrace.com/knowledge/general-faqs)
- [Key MEPC Regulations and Rivertrace Solutions](https://hub.rivertrace.com/knowledge/key-mepc-regulations-and-rivertrace-solutions)
- [OCD CM](https://hub.rivertrace.com/knowledge/ocd-cm)

[![Rivertrace-Logo-Black](https://hub.rivertrace.com/hs-fs/hubfs/Rivertrace%20Logos/Rivertrace-Logo-Black.jpg?width=271&height=99&name=Rivertrace-Logo-Black.jpg "Rivertrace-Logo-Black")](https://www.rivertrace.com)

Rivertrace Product, Regulation and Technical Support Knowledge Base

<https://www.linkedin.com/company/22297015>

Copyright © 2025, Rivertrace Limited