Rivertrace MEPC.107(49) Compliant equipment overview

This is an in depth view of how Rivertrace have responded to marine pollution prevention guidelines with our Smart Bilge oil content meter.

Rivertrace are world leaders in the measurement of free oil in water.

What is bilge water? 

Due to the natural shape and layout of a ship, along with gravity, any spillage, machinery leakage etc. in an engine room or machinery space on board a vessel will mean that the lowest point within that space will accumulate wastewater (Bilge water). This bilge water is predominantly water but due to its proximity to machinery, there is a high chance of oil contamination. 

What can the crew do with bilge water? 

It is legal for vessels to discharge bilge water back into the ocean providing that certain parameters are met. Uncontrolled levels of oil discharged into the ocean can have a dramatic impact on the environment. Oil cannot dissolve in water and leaves a thick sludge which can endanger marine life and the surrounding environment.

What are the rules? 

According to the Marine Environment Protection Committee, also known as  MEPC, all ships of 400 gross Tons and above, with a keel laid or a similar stage of construction on or after the 1st January 2005 must operate in accordance with a set of guidelines called MEPC.107(49). This is enforced globally and failure to comply can result in fines in excess of $1million and vessels detained. Marine pollution prevention is taken very seriously. 

MEPC.107(49) was adopted on the 1st January 2005 and is still current today after superseding the old MEPC.60(33) regulation that was the standard between the 30th October 1992 and 1st January 2005.

Engineers working with equipment relating to these guidelines must ensure that they are familiar with them to ensure that their work does not impact the compliance of the vessel. 

How is it discharged? 

New technologies over the last thirty years, such as oily water separators and oil content meters have been developed to ensure vessels can demonstrate compliance to the relevant pollution preventative guidelines. 

The oily water separator is a piece of equipment that is used to separate oil and water mixtures into their separate components. Oily water separators can be designed to treat a variety of contaminants in water, including free floating oil, emulsified oil, dissolved oil and suspended solids.  Oily Water separators, generally referred to as OWS are primarily used for bilge water discharges. The OWS Is typically installed low down in the engine room. 

OWS location 

In general, every ship over 400 gross tons will have an approved OWS installed on the discharge pipe between the bilge and overboard. The bilge water is pumped through the OWS, where oil will be removed before passing overboard. 

To ensure that the OWS is performing correctly and that a very limited quantity of oil is in the bilge water (Within MEPC.107(49) guidelines), an Oil Content Meter (OCM) is installed to measure the oil content of the bilge water at the separator outlet. This is where the Rivertrace Smart Bilge Oil Content Meter (OCM) is installed. The Smart Bilge is an Oil Content Monitor designed, developed, manufactured and serviced by Rivertrace Limited. 

The Smart Bilge will continuously monitor the bilge water being discharged and automatically divert all water back to the bilge tank if the oil content rises above the pre-set alarm point, by controlling an "Automatic Stopping device" (3-way Valve). The standard oil content limit for a legal discharge is 15ppm (Parts Per Million) according to the MEPC.107(49) guidelines. To put this quantity of oil into context, this is 15mL of oil in 1000 litres of water. 

 

Smart Bilge overview

 

With this configuration, discharges are monitored automatically and excess oil is prevented from being discharged. When the oil content exceeds the alarm point (typically 15ppm maximum), the water is diverted back to the bilge tank. This state recirculates the water, continuously stripping oil as the water passes through the OWS until the water leaving the OWS drops back below the alarm point. At this stage, the "Automatic Stopping device" (3-way valve) will open once more to allow the discharge of water overboard to commence. This process will continue until the pump moving the water is stopped, either manually by crew or automatically by liquid level sensors in the bilge tank.

Smart Bilge MEPC.107(49) OCM information

 

 

 

All details regarding the serial number, supply voltage, date of manufacture and approvals can be fount typed onto the silver rating label, fixed to the bottom left corner of the Smart Bilge backplate, below the Controller module. 

The Smart Bilge monitor is split into two modules; the Controller module and the measuring cell. 

The controller module, located on the left of the Smart Bilge, performs the following;

  • Houses and drives the LCD Display where Time, Date, PPM, alarm states and fault messages are visible. 
  • Houses and drives the buttons used to navigate the menus. 
  • Receives mains power and distributes power to the measuring cell. 
  • Contains two alarm relays. Alarm 1 must be used for directly controlling an "Automatic Stopping Device" (typically a 3-way diverter valve) and Alarm 2 is used to control an audible alarm supplied by the vessel. 
  • Drives the sample / Clean solenoid valve as required. 
  • Holds the Clock and IMO Data memory. 
  • Has a mA output terminal that will emit an active 4-20mA Output, representing the PPM value, for remote displays. 
  • Has a switch input that MUST be wired to volt free contacts within the separator that close when the oily water separator is running. This is a legal requirement. This is the "Separator Input Status". 

The measuring cell, located on the right of the Smart Bilge, performs the following;

  • Holds the calibration and can be swapped out to renew the calibration as and when required. 
  • Analyses the bilge water and sends the calculated PPM value to the controller module. 
  • The Measuring cell must be calibrated every 5 years or at the IOPP Renewal. We also recommend that the measuring cell is verified annually onboard with a verification kit. 

The Smart Bilge OCM meets and exceeds all requirements set out by MEPC.107(49). The specifications in the table below are for our standard offering. 

Smart Bilge OCM data

As with all MEPC.107(49) Oil in water analysers, there are flaws within the regulation that do not protect against malicious or even accidental tampering of the OCM. Rivertrace have identified these areas and have robust solutions in place to bolster the standard Smart Bilge OCMs security and reliability. 

The most prominent cause of OCM failure is undoubtedly soiling of the optical components within the measuring cell. Rivertrace have a bolt-on accessory to tackle this manufacturer wide problem. A pneumatic Auto-Clean system can be easily installed to any Rivertrace Smart Bilge monitor to automatically clean the optics on adjustable, timed intervals. With crew already stretched, this inexpensive system increases service intervals and reduces man hours needed for periodic maintenance. 

Autoclean system

Another known problem with OCMs on board vessels is that the flow through the measuring cell is rarely checked. This means that it may be possible to trap clean water inside the measuring cell to allow a discharge to take place without measuring the oil content of the actual water leaving the OWS and passing overboard. The result is an unmonitored, illegal discharge. This can occur through a malicious act by OWS operators or due to something as simple as a blocked sample pipe. Whatever the cause, Rivertrace have a solution in which a flow switch is fitted to the measuring cell inlet. If no flow is detected passing through the measuring cell, an alarm is triggered and the automatic stopping device (3-way valve) at the separator outlet is closed to recirculate all flow back to the bilge tank until flow is detected once more. 

flow switch

Both of these additions can be retrofitted and also fitted together to result in a very robust and secure OCM. 

Autoclean and flow switch

On top of these additions, Rivertrace offer a verification sample kit that can be used by crew to verify and demonstrate the accuracy of the Smart Bilge measuring cell. Two bottles of fluid are provided per kit allowing the operator to demonstrate the accuracy at both 10ppm and 20ppm. These points have been selected so that they straddle the alarm point which is typically set to 15ppm. The 10ppm verification kit will demonstrate that the Smart Bilge monitor will allow a discharge when the PPM is below the alarm point. The 20ppm solution will demonstrate that the Smart Bilge will prevent a discharge should the PPM rise above the alarm point at 15ppm. 

The Factory calibration is valid for 5 years. The calibration can only be performed by Rivertrace at the Rivertrace factory. Replacement calibrated parts can be purchased and installed by crew, renewing the calibration certificate for a further 5 years. 

Where can a bilge discharge take place? 

Amongst other factors, the vessel's speed and position dictate when a discharge of bilge water containing less than 15ppm of oil is permitted from the OWS system, according to MARPOL (The International Convention for the Prevention of Pollution from Ships). 

As an overview, the below list highlights the key rules set out by MARPOL

  • The Ship is proceeding en route.
  • The bilge water has been processed by a suitably approved OWS. 
  • The oil content of the bilge water is less than 15ppm without dilution. 
  • The oil content of the bilge water does not originate from cargo pump-room bilges (on board oil tankers).
  • The bilge water is not contaminated with cargo oil (on board oil tankers). 

Although MARPOL set the international regulation for pollution prevention, this is a minimum. Often nations, regions and even states have tighter restrictions to meet on top of these MARPOL regulations. Some special areas of ocean are protected and no discharges may take place at all. 

Ultimately, the ship's crew are responsible for determining if the ship is in a location where a discharge is permissible. 

What else happens? 

With each movement of oil on board a vessel, an entry must be made into an "Oil Record book". This is effectively a log that tracks the movements of all oil on board a vessel be it within the vessel, boarding the vessel or being discharged from the vessel. This is usually a paper log book that is manually written with a pen. Failure to keep this Oil Record Book accurately maintained will result in large fines, on par with fines for illegal discharging oil. This is the vessels responsibility.  Some vessel's and regulating bodies are now starting to adopt digital oil record books as opposed to paper copies. 

Oil record book

Alongside the Oil Record Book, the OCM must record key data from each discharge. According to and exceeding MEPC.107(49), the Smart Bilge records date, time, alarm status, and operating status of the 15 ppm Bilge Separator along with the measured PPM when the log entry was made. The Smart Bilge can also store data for at least eighteen months and can display it for official inspections as required on board for 18 months. This is referred to as "IMO Data". This IMO Data can also be copied to a local computer if required, in a text format. 

Who Checks? 

There are numerous ways of illegal discharges or even discharge data discrepancies being highlighted to authorities. Whistle-blowing is one method, where crew may witness illegal discharges taking place maliciously or even accidentally and report it. This is usually financially incentivised by authorities to encourage this to happen.  

3rd parties such as neighbouring vessels or coastguards may also witness illegal discharges or even the resulting oil spill from an illegal discharge and track which vessel may have been responsible, using the GPS locations of vessels that have been in the area. 

The vessel may have accidently performed an illegal discharge and inform the authorities of this, taking the appropriate action to correct the mistake. 

Sometimes no discharge is necessary for fines to be issued. Often, data discrepancies between the OCM data, tank levels and the oil record book suffice. These discrepancies are usually picked up by official surveyors who survey vessels each time a port visit is made. In general, the surveyors who board the vessels in port will want to see the Oil Record Book, IMO Data inside the Smart Bilge and a demonstration of the OCM directly controlling the automatic stopping device at the OWS when 15ppm is exceeded, preventing a discharge in accordance with MEPC.107(49)

To aid this process, Rivertrace have recently added a new feature aimed at surveyors and anyone who may wish to witness the functionality of the Smart Bilge monitor. This is a button that can be pressed to start a demo cycle where the PPM will sweep from low to full scale and back down again to demonstrate the alarms tripping as the displayed PPM Sweeps past the alarm set point. This can be retrofitted to older monitors that are already in the field. 

Support

Alongside our expansive agent network, Rivertrace are embracing digital and all it has to offer. One aspect of this that is proving invaluable is our ever growing "Knowledge base",  which is published on our website. The vast majority of queries from vessels, service engineers and others, outside of and within Rivertrace are published and explained here. This area is dedicated to "How To" guides, fault finding instructions, standard procedures and expert advice.